The Fort Worth Press - France's City of Light switches to climate-resilient power cables

USD -
AED 3.673014
AFN 68.000018
ALL 90.497685
AMD 387.14973
ANG 1.80291
AOA 914.498294
ARS 974.741102
AUD 1.485432
AWG 1.80175
AZN 1.657375
BAM 1.788618
BBD 2.019845
BDT 119.542753
BGN 1.790898
BHD 0.376965
BIF 2892.5
BMD 1
BND 1.308539
BOB 6.912539
BRL 5.577607
BSD 1.000366
BTN 83.985478
BWP 13.303033
BYN 3.27377
BYR 19600
BZD 2.016424
CAD 1.375535
CDF 2875.000023
CHF 0.85674
CLF 0.03368
CLP 929.329829
CNY 7.079799
CNH 7.084415
COP 4210.25
CRC 516.593355
CUC 1
CUP 26.5
CVE 101.400294
CZK 23.211035
DJF 177.72027
DKK 6.831499
DOP 60.410079
DZD 133.305989
EGP 48.578998
ERN 15
ETB 121.18715
EUR 0.91567
FJD 2.249025
FKP 0.761559
GBP 0.766375
GEL 2.724983
GGP 0.761559
GHS 15.959419
GIP 0.761559
GMD 67.999787
GNF 8634.999846
GTQ 7.736555
GYD 209.287439
HKD 7.770397
HNL 24.829777
HRK 6.799011
HTG 131.796982
HUF 367.29822
IDR 15691
ILS 3.76745
IMP 0.761559
INR 83.959602
IQD 1310
IRR 42090.000105
ISK 136.160255
JEP 0.761559
JMD 158.074753
JOD 0.708699
JPY 148.778979
KES 128.999947
KGS 85.233153
KHR 4068.999634
KMF 451.450333
KPW 899.999433
KRW 1352.479738
KWD 0.30651
KYD 0.833646
KZT 496.177412
LAK 21869.99999
LBP 89790.305947
LKR 292.985825
LRD 192.902396
LSL 17.71495
LTL 2.95274
LVL 0.60489
LYD 4.802706
MAD 9.83375
MDL 17.686167
MGA 4580.000404
MKD 56.398427
MMK 3247.960992
MNT 3397.999955
MOP 8.007627
MRU 39.764997
MUR 46.109576
MVR 15.359763
MWK 1735.000133
MXN 19.520898
MYR 4.291498
MZN 63.874982
NAD 17.715023
NGN 1620.290202
NIO 36.830295
NOK 10.746181
NPR 134.378286
NZD 1.64343
OMR 0.384952
PAB 1.000348
PEN 3.75925
PGK 3.930973
PHP 57.455042
PKR 277.65052
PLN 3.937295
PYG 7801.697333
QAR 3.640994
RON 4.555966
RSD 107.142432
RUB 96.59825
RWF 1351.5
SAR 3.754939
SBD 8.265027
SCR 13.238946
SDG 601.501836
SEK 10.40997
SGD 1.30762
SHP 0.761559
SLE 22.847303
SLL 20969.494858
SOS 570.999718
SRD 32.11399
STD 20697.981008
SVC 8.753704
SYP 2512.529936
SZL 17.579805
THB 33.490164
TJS 10.653852
TMT 3.5
TND 3.076006
TOP 2.342101
TRY 34.200298
TTD 6.79189
TWD 32.285502
TZS 2725.000279
UAH 41.241621
UGX 3676.268861
UYU 41.573691
UZS 12790.000255
VEF 3622552.534434
VES 37.482013
VND 24845
VUV 118.722009
WST 2.797463
XAF 599.863742
XAG 0.032202
XAU 0.000381
XCD 2.70255
XDR 0.744209
XOF 599.497138
XPF 109.824971
YER 250.420974
ZAR 17.534694
ZMK 9001.191317
ZMW 26.559185
ZWL 321.999592
  • RBGPF

    2.5500

    63.35

    +4.03%

  • RYCEF

    -0.0200

    6.88

    -0.29%

  • SCS

    -0.4300

    12.6

    -3.41%

  • CMSC

    0.0700

    24.59

    +0.28%

  • NGG

    0.0500

    65.68

    +0.08%

  • VOD

    0.0100

    9.74

    +0.1%

  • BCC

    -3.4400

    138.95

    -2.48%

  • RELX

    -0.3500

    46.36

    -0.75%

  • RIO

    0.4900

    66.84

    +0.73%

  • CMSD

    0.0900

    24.77

    +0.36%

  • BCE

    -0.4500

    32.86

    -1.37%

  • JRI

    0.0000

    13.22

    0%

  • AZN

    -0.6350

    76.87

    -0.83%

  • GSK

    -1.0300

    39.21

    -2.63%

  • BTI

    -0.3700

    35.11

    -1.05%

  • BP

    0.3600

    32.34

    +1.11%

France's City of Light switches to climate-resilient power cables
France's City of Light switches to climate-resilient power cables / Photo: © AFP

France's City of Light switches to climate-resilient power cables

To maintain the glow of the City of Light, Paris is modernising its underground electric cables, vulnerable to damage during heatwaves and dating back 60 years.

Text size:

With power cables melting from Portland to Sicily, the world's 80 million kilometres (50 million miles) of power lines are largely unprepared to resist extreme temperatures, scientists have warned.

The French capital over the next few months will be replacing its obsolete paper-insulated lead-covered cables (PILC), which are made of oil-impregnated paper encased in a lead sheath.

"We're anticipating the renewal of these cables, which are starting to be affected by heat, to have a very resilient network in Paris," said Olivier Lagnel, deputy regional director for utility firm Enedis.

Nearby, workers in orange vests worked in a trench close to the Montparnasse train station to replace the medium voltage PILC, which were installed in 1965, with modern, plastic cables.

State-owned Enedis says Paris is not alone: its counterparts in Chicago, London, Shanghai, Hong Kong, Osaka, Tokyo, Singapore and Sydney also plan to update their cables.

- 'Climate emergency' -

Trouble has mounted in recent years.

Paper-insulated during a 2003 heatwave in France showed weaknesses with "an incident rate multiplied by eight across the medium-voltage underground network", according to a March 2024 report by France's Court of Audit.

Overhead tramway cables melted in Portland in 2021 during record-high temperatures in the northwest US state of Oregon.

A searing heatwave in July 2023 left hundreds of thousands of Sicilians without electricity and water for days.

Heat damage to underground cables was to blame, said supplier e-distribuzione, the distribution arm of energy giant Enel.

"We find ourselves operating in conditions of exceptional climatic emergency," where the temperature of the asphalt on roads reached 50 degrees Celsius (122 degrees Fahrenheit), it said in a statement at the time.

A 2021 study led by Alessandro Bosisio, an assistant professor at the University of Pavia in Italy, found that "an abnormal increase of faults in underground Medium Voltage cable joints has been recorded, especially during summer" worldwide in recent years.

Climate scientists say the period being lived through right now is likely the warmest the earth has seen for the last 100,000 years, back at the start of the last Ice Age.

- Avoid cuts -

PILC cables, which were the international standard from the late 19th century until the 1970s, were long considered highly reliable.

They were wrapped in layers of oily paper intended to isolate the centre of the cable, which heats up as electrons pass through.

The cables were conceived to resist temperatures up to 90C (194F). But when heat is trapped for days under the asphalt, they can reach 120-130C (248-266F) -- ageing faster and eventually risking failure.

Paris's 9,200 kilometres of low- and medium-voltage power cables are entirely buried underground -- to save space and protect them from the wind, Lagnel said.

Enedis plans to phase out the obsolete cables in French cities by 2050.

"The main problem is that the insulator can dry up, and in that case the cable can be sensitive," said Lagnel.

"The idea is to avoid cuts as much as possible" and to "desensitise the network... as heatwaves come back more and more often, stronger and stronger."

N.Patterson--TFWP